RPIC Control Station Power Failure
RPIC Control Station Power Failure
Loss of RPIC Control Station Power
WARNING: Loss of RPIC Control Station Power may result in loss of RPIC awareness into aircraft behavior that could result in any of the following: minor injuries, minor damage to manned aircraft, substantial damage to unmanned aircraft weighing at least 55 pounds (MINOR)
INDICATIONS
- Physical Loss of RPIC Control Station
- RPIC Control Station is unresponsive
FAILSAFE BEHAVIOR
If RPIC Control Station Connectivity is lost during the inbound mission phase, the aircraft continues with the planned mission (returning to home location and precision landing).
If RPIC Control Station Connectivity is lost during the outbound mission phase, the aircraft holds above the delivery location until the low energy storage device failsafe is enabled.
PROCEDURE
EMERGENCY LOSS OF RPIC CONTROL STATION POWER ANNOUNCE
Record last known location — NOTE B.A.T.H.S
Re-establish RPIC Control Station connectivity to aircraft — ATTEMPT
If connection is reestablished in 45 seconds or less:
Mission — CONTINUE
Procedure Complete
If connection cannot be reestablished in less than 45 seconds:
Active LTE on tablet VERIFY
Mission Console — OPEN ON RPIC TABLET
Uncrew: Return to Home SELECT
Procedure Complete
Last updated on